Over a period of 12 months ending April 2001, Advantica* carried out a series of independent tests on Corrosion Master at its world renowned research centre in Loughborough UK. The test objectives were as follows:

  • to test the effectiveness of Corrosion Master in reducing dissolved oxygen levels in a wet central heating system.

  • to evaluate the corrosion protection qualities with mixed metals typically found in wet central heating systems.

Dissolved Oxygen Reduction
Repeat tests confirmed that the product clearly demonstrated its ability to reduce dissolved oxygen levels from both fill water and simulated pump over conditions
.

Oxygen Monitoring data after cold pump over

Galvanic Current Monitoring after cold pump over

Corrosion Protection Qualities
Weight loss measurements taken from metal coupon samples (with 1mm wall thickness) in a system fitted with Corrosion Master demonstrate the material life as detailed below.

 

"Advantica* confirms, from its testing of Corrosion Master, that the product offers outstanding corrosion protection for all metals typically found in wet central heating systems".

*Formerly part of British Gas plc.
Advantica logo reproduced with permission.

 

TECHNICAL DATA: Corrosion Master Products

General Product Information
Oxygen plays a central role in the corrosion of central heating systems, entering in the form of dissolved oxygen (D.O.) via tap water used for filling. As fire dies upon the removal of oxygen so the corrosion process also ceases.

Corrosion Master significantly retards the corrosion process by raising the pH and restricting the amount of D.O. in the water. Once the D.O has been eliminated the unit shuts down to be automatically reactivated upon the introduction of fresh oxygenated water. Additionally Zinc species that polarize existing corrosion cells are released into the water.

Product Life
The CM5 and CM10 are designed to continue working unattended for 5 and 10 years respectively and are supplied with an installation date Fitting Location Central heating system, closed circuit Position Fitted in flow or return of heating circuit. Power Source Not required. Fitting Instructions Supplied with packaging, available on request.

Additional Information
During the year 2000 Scalemaster submitted its Corrosion Master product to BG Technology for independent testing at its Gas Research & Technology Centre in Loughborough, UK. This world-renowned research establishment has considerable expertise in the field of corrosion. Extracts from their report are available on request.

Download this Technical Datasheet as pdf file

Application
Scalemaster Corrosion Master is designed to inhibit corrosion, scale and bacteria in domestic hot water heating systems.

Fitting Location
Central heating system, closed circuit.

Position
Fitted in flow or return of heating circuit.

Power Source
Not required.

Fitting Instructions
Supplied with packaging, available on request.

Operating information
Designed and tested for use in wet central heating systems. Pressure tested to 14 bar. Maximum working pressure 8 bar.

Site Requirements
Prior to installation the heating circuit should be flushed out thoroughly with either a Cleaner or Sludge remover such as Scalemaster SM3 or SM4 in line with BS 7593.

Approvals
The product packaging carries an endorsement from BG Technology (formerly part of British Gas) with regard to the ability of product to absorb dissolved oxygen with its effect on corrosion activity

Scalemaster reserves the right to change specifications without prior notice.